logo-01

Parallel output multi-turn absolute encoder CAX60 series

  • Multi-turn absolute encoder (mechanical gear structure)
  • Detection method: magnetoelectric encoder, Hall principle
  • Operating voltage: 10…30Vdc polarity protected
  • Output signal: Parallel output (pure binary, Gray code or Gray remainder)
  • Programmable, intelligent absolute encoder, professional setting software, user-friendly operation
    With setting line, easy to install and debug
  • Resolution: ≤12 bits, up to 4096 lines (order option)
  • Laps: 4096 laps
  • Outer diameter 60mm, inner hole/shaft diameter 6-15mm optional
  • Protection class: shell IP67, shaft IP65
  • Vibration and shock: 20g, 10~2000Hz; 100g, 6ms
  • Allowable speed: 6000 rpm
  • Software and hardware can be customized according to actual needs

Mechanical parameters

Electrical parameters

maximum speed

6000 rpm

Operating Voltage

10-30Vdc (5Vdc can be customized)

Spindle load

Axial 40N, Radial 100N

current consumption

< 300mA (24Vdc) no load

impact resistance

1000m/s²(6ms), equal to 100g

output signal

25-bit synchronous parallel signal (pure binary or gray code)

Anti-vibration

200m/s²(10-2000Hz), equal to 20g

Linear resolution

1/4096FS and 1/8192FS

Allow axial play

±1.5mm

Maximum working laps

4096 laps (256 laps/64 laps optional)

Allow radial runout

±0.2mm

Repeatability

<2Bit

external structure

60mm OD, solid shaft, blind hole shaft

Operating temperature

-40℃~85℃ 

Connection Type

30 core shielded cable or aviation plug

Storage temperature-40℃~85℃

reliable and patented

l Strong bearing structure with Safety-Lock TM design, which can provide higher vibration resistance and installation error resistance

l IP68 protection grade and wide operating temperature range -40℃…+85℃

l Patented mechanical gear technology, with permanent power-off memory function

 

performance optimization

l High precision, data refresh rate of location data ≤ 4us

l Direct reading through I/O port

l International standard SSI signal format

Wiring diagram

Black/1

20

orange/3

28

Ash/3

216

brown/3

224

Note:

1. Parallel output reference voltage, voltage drop of <2V per bit is normal. Please use short-circuit with the positive (brown) power supply.

2. Set: connect to 24V + 1 second to set the current value to zero.

3. Forward and reverse: counterclockwise data increase when connected to 24V+

4. Parallel output maximum 50mA per bit

5 Active high.

Black/2

21

Purple/1

29

blue/2

217

 

 

Black/3

22

Purple/2

210

blue/3

218

 

 

Green/1

23

Purple/3

211

Red/2

219

Red/1

KVCC

Note 1

Green/2

24

yellow/1

212

Red/3

220

Ash/1

Set   Note 2

Green/3

25

yellow/2

213

white/2

221

Brown/1

10-30Vdc

Orange/1

26

yellow/3

214

white/3

222

white/1

GND 0V

Orange/2

27

Ash/2

215

brown/2

223

blue/1

Forward and reverse Note 3

Mechanical dimension drawing

Clamping synchro flange (optional for cable output or plug output)

Synchronous flange/servo flange (cable output or plug output optional)

Blind Hole/Half Through Hole Flange (Cable output or plug output optional)

output signal
The output is a parallel push-pull output signal, which is connected to the input module (I/O) of the PLC as shown in the figure below:

Note: When the encoder is connected in PNP mode, the parallel signal line is effective at high level, and when the encoder is connected in NPN mode, the parallel signal line is effective at low level.