Specification
Operating Voltage | 10-26Vdc or 5V polarity protection |
Current Consumption | < 80mA (24V power supply) no load |
Output Signal | RS485 output, you can set the length, angle, speed application output |
Output load capacity | ≤ 400 ohms, the standard 200-250 Ohm work |
Linearity Resolution | 1/4096 |
Revolution | Up to 4096 Clock-type gear structure |
Operating Temperature | -20—80℃ Programming temperature range:0℃~+70℃ |
Storage Temperature | -40—80℃ |
Protection class | IP67 for housing IP65 for shaft |
Vibration & shock | 20g,10~2000Hz;100g,6ms |
Permissible Rotation Rate | 2400rpm |
Output refresh cycle | <1.4ms |
Connection Cable | 1m 8-core shielded cable. |
Overall Feature | Clamping flange or synchronous flange, metal enclosure, sealed dual-bearing structure ( see attached drawing of overall dimension) |
Instance
Read data:
Host send: D + address + 0D
Encoder reply: X + address +> + match bit + data bit + 0D
Example:
Host send: 44 30 31 0D (when the encoder address is 01)
Encoder back: 58 30 31 3E 2B 30 30 30 30 30 30 30 31 32 33 0D
Encoder reset command:
Host send: D + address + L + M + sum check + 0D
Encoder reply: X + address + l + m + sum check + 0D
Example:
Host send: 44 30 31 4C 4D sum check 0D (when the encoder address is 01)
Encoder reply: 58 30 31 6C 4D sum check 0D (reset current position)
Installation dimensions (mm)
Clamping (default)
synchro flange
Blind hollow shaft
Featured software
By the professional PC setting software provided by CALTSENSOR, you can easily modify the counting direction, working mode, address, baud rate, resolution, and reference bit of the encoder; and Observe the current encoder data in real time.
If needed, please click this button to download the associated software.