Displacement Indicator BL9648 series

  • Power supply: 24VDC
  • Input Impedance: 5K
  • Magnification range: 0.000 to 999.999
  • Display range: -999999 to 999999
  • Pulse level: Low level: -50V~0.5V High level: 3.5~50V
  • Contact capacity: AC220V1A DC24V1A
  • Ambient temperature: -10℃~50℃
  • Product Name: Cable Displacement Sensor Digital Display Instrument BL9648 Series
  • customizable

Technical characteristics

The BL9648-ii display is a five-digit display module for position, control and display. It can be widely used in the field of industrial control.

◆ Internationally used 96×48×115mm standard chassis, five-digit 0.56 inch digital tube display.

◆ Input pulse signal.

◆ Equipped with an external clear terminal, which can be cleared by an external switch.

◆ Set two control values and two relay outputs, which can be used for control or alarm.

◆ Optional 3 kinds of relay output modes.

◆ The automatic delayed reset time can be set to realize the automatic delayed reset function.

◆ Peak display function.

◆ It can count/count the speed, set by internal parameters.

◆ Parameter setting password protection function.

◆ The current count value and set value will not be lost when power off.

◆ The magnification can be set to determine the proportional relationship between the input signal and the displayed value.

◆ External sensor: angular and linear displacement grating sensor, providing 5V (100mA), 12V (100mA) power supply to the sensor.

◆ Calibration function: 9 calibration points can be set to realize the linear difference compensation function.

Technical Parameters

◆ Power supply voltage: AC220V default,24Vdc optional

◆ Input impedance: 5K

◆ Magnification range: 0.000~999.999

◆ Display range: -999999~999999

◆ Pulse level: low level: -50V~0.5V high level: 3.5~50V

◆ Contact capacity: AC220V1A DC24V1A

◆ Installation method: snap-in

◆ Hole size: 92×43. 5mm

◆ Ambient temperature: -10℃~50℃

Parameter Description

Code

Description

Setting range

Defaults

Pn-00

The position of the decimal point (the number of decimal places in the displayed value).

0~6

2

Pn-01

Counting frequency 0-single frequency, 1-double frequency, 2-quadruple frequency

0~2

1

Pn-02

Counting magnification, after linear calibration, this item will be invalid.

0.000~9999.999

1.000

Pn-03

The upper limit and the decimal point are defined by settings.

0~9999999

500

Pn-04

The lower limit and the decimal point are defined by settings.

0~9999999

10

Pn-05

Counting direction, 0 means positive counting.

0/1

0

Pn-06

Initial value, this item is an integer without decimal point

0~9999999

0

Pn-07

Parameter protection password, when it is not zero, the parameter is protected by password.

0000~9999

0000

Pn-08

The unit of relay reset time is second, 0.0 means no reset. Note 1.

0.0-999999.9

0.0

Pn-09

Enter the filter coefficient, 0 means no filtering, and level 5 is the strongest.

0~5

0

Pn-10

485 communication address, see communication protocol for details.

00-99

01

Pn-11

Pn-08 is 0 when the lower limit relay action mode, 0-below the lower limit action 1-above the lower limit action, but has nothing to do with the upper limit, 2-over the lower limit action, if the upper limit is reached, it will reset. If Pn-08 is non-zero, this item is invalid.

0~2

0

Pn-12

The input pulse form selects 0-quadrature code input 1-single input. For single input, both can be connected to AB.

0

0

Pn-13

485 serial port baud rate setting 600~9600 bps, Note 2

0~5

5

Speed parameter

Code

Description

Setting range

Defaults

S n-00

The position of the decimal point (the number of decimal places in the displayed value).

0~4

2

S n-01

Speed unit: 0-mm/s 1-mm/min 2-m/h

0~2

0

S n-02

Speed multiplier, the speed value can be corrected

0.000~9999.999

1.000

S n-03

The upper limit and the decimal point are defined by settings.。

0~99999

300

S n-04

The lower limit and the decimal point are defined by settings.

0~99999

50

S n-05

Speed measurement mode. 0 is the instant speed; 1-5 is the speed average time, in seconds.

0~5

0

S n-06

The reset time unit of the speed relay is second, 0 means no reset, note 1.

 

 

S n-07

When S n-06 is 0, the lower limit relay action mode is the same as Pn-11. If S n-06 is non-zero, this item is invalid.

 

 

Wiring definition

Signal

name

Output supply

Output supply

External reset

Draw wire displacement sensor

External terminal

+12v

+5v

GND

Reset

A

B

A-

B-

Upper terminal

9

10

11

12

13

14

15

16

                                                           

Lower terminal

1

2

3

4

5

6

7

8

External terminal

L

N

J1 Relays

J2 Relays

spare

 

24Vdc

Normal open

Normal open

Custom for rs485

Main display window: Display current displacement

 

Secondary display window: Display speed  

Parameter setting

1 When there is no password protection

 

 

1) Press the function key (MO) during normal operation in one second, the secondary display window will display Pn-00; the current parameter value of the main display window, you can use the ↑ key to cycle through the display until the parameter you want to modify Pn-XX

2) When the parameter “Pn-XX” is displayed in the secondary window, press the enter key (En) to enter the parameter setting state, and the parameter displayed in the main window is blinking;

3) To modify the value, make sure that the current modified digit is the blinking digit. If it is not, press the function key (MO) to change the position of the blinking digit in turn from right to left. Different parameters display different digits. Use the ↑ key to change

 

 the value, after setting the parameter, press the enter key (En) to jump out of the setting of the parameter Pn-XX,

4) Press (MO) to return to working state.

5) When entering any state in the setting, if you press the clear key (CL.), it will not save and exit, but the parameters just modified are temporarily effective before the power is turned off (except the serial port baud rate), and will be re-powered. Restore the previous setting value. This function can be used to view parameters.

1.1 Enter the speed setting interface

1) Press the function key (MO) for more than 2 seconds during normal operation, the secondary window will display Sn-00, and the main window will display the current parameter value. The steps for switching, modifying, and saving are the same as the previous steps.

  1. When there is password protection

Press the function key and enter the corresponding setting according to the above method, the main window will display “Pn-CO.” and enter the password input state. At this time, the window displays 0000 and the lowest digit flashes. Refer to the above operation, enter the correct password through the ↑↓ key and the function key (MO), press the OK key (En) to confirm, and the program enters the parameter setting state. If the password is entered incorrectly or the clear key (CL.) is pressed, the program returns to the working state.

Restore factory settings

In the working state, press the ↑ key and the EN key at the same time, and the buzzer will beep for more than 5 seconds. Then it will restore the factory settings.

Reviews

There are no reviews yet.

Be the first to review “Displacement Indicator BL9648 series”

Your email address will not be published. Required fields are marked *

Customize your Own sensors

Just write down some details and our our customer service get back to you in a jiffy!