Specification
Operating Voltage | 18-26Vdc polarity protection |
Current Consumption | < 110mA (24V power supply) no load |
Output Signal | RS485 and 4-20mA dual independent output(0-5V, 0-10V optional), you can set the length, angle, speed application output |
Output load capacity | ≤ 400 ohms, the standard 200-250 Ohm work |
Linearity Resolution | 1/4096 |
Revolution | max.4096(Wiegand principle) |
Operating Temperature | -20—75℃ Programming temperature range:0℃~+70℃ |
Storage Temperature | -40—80℃ |
Protection class | IP67 for housing IP65 for shaft |
Vibration & shock | 20g,10~2000Hz;100g,6ms |
Permissible Rotation Rate | 2400rpm |
Output refresh cycle | <1.4ms |
Connection Cable | 1m 8-core shielded cable. |
Overall Feature | Clamping flange or synchronous flange, metal enclosure, sealed dual-bearing structure ( see attached drawing of overall dimension) |
Signal Conditioning | Can 4mA output trim, 20 mA output trim; direction can be set; preset position, external set, such as external zero |
Example (output signal evolution)
Installation dimensions (mm)
Clamping (default)
synchro flange
Blind hollow shaft
Featured software
By the professional PC setting software provided by CALTSENSOR, you can easily modify the counting direction, working mode, address, baud rate, resolution, and reference bit of the encoder; the analog signal ZERO and full scale corresponding data; and Observe the current encoder data in real time.